Jump past the menu
GI Nurse Certifications

Part of Domain 2 · Gastroenterological Procedures (35%)

Impedance-pH, Bravo, manometry and other non-scope tests

Impedance-pH and wireless capsule reflux testing, manometry, breath tests, gastric emptying, paracentesis and liver biopsy: tests done without an endoscope, or with one only to place a device, are subdomain 2B, part of Gastroenterological Procedures (35%). Blueprint 2B has the nurse perform these tests, not only assist, so preparation, the procedure and discharge teaching are all in scope.

Revised

Tried 0 of 18 so far; 0 right

No. 1 of 18

A patient with dysphagia and a normal EGD is scheduled for high-resolution esophageal manometry. The nurse understands this test is ordered MAINLY to:

  1. A manometry catheter carries pressure sensors, not forceps; Barrett's esophagus is confirmed by biopsies taken at endoscopy.

  2. Structural causes of dysphagia are found by EGD or barium study; the normal EGD is the reason the motility test comes next.

  3. Acid exposure is measured by pH or pH-impedance monitoring; both tests use a nasal catheter, which is why they get mixed up.

  4. High-resolution manometry records pressure along the esophagus during wet swallows and grades peristalsis and LES relaxation, the basis of the Chicago Classification.

See the answer before picking
No. 2 of 18

During EGD, a duodenal aspirate is collected for culture in suspected small intestinal bacterial overgrowth (SIBO). Which technique BEST reduces contamination?

  1. Fixative kills organisms; it is for cytology or histology, never for culture.

  2. A sterile catheter passed down the channel collects duodenal fluid that has not touched the oral and gastric flora lining the scope's own channel.

  3. Saline dilutes the sample, and the diagnosis depends on colony counts per milliliter.

  4. Fluid drawn up the working channel picks up mouth and stomach organisms on the way, contaminating the culture and inflating colony counts.

See the answer before picking
No. 3 of 18

A patient completes off-PPI ambulatory reflux monitoring. Per the Lyon Consensus 2.0, which result provides conclusive evidence of GERD?

  1. Reflux episode counts are an adjunct metric (Lyon 2.0 calls more than 80 supportive), so a count above 40 is not conclusive evidence.

  2. A value of 4% to 6% is the borderline zone; it needs supporting metrics or symptom association and does not settle the diagnosis by itself.

  3. Acid exposure below 4% is physiologic and argues against GERD, the opposite end of the scale.

  4. Lyon Consensus 2.0 treats an off-PPI acid exposure time above 6% as conclusive evidence of pathologic reflux.

See the answer before picking
No. 4 of 18

During anorectal manometry, the patient is asked to bear down as if having a bowel movement. Which function does this maneuver assess?

  1. The reflex is triggered by rapid balloon distention and shows internal sphincter relaxation; it needs no effort from the patient.

  2. Simulated evacuation tests the coordination of defecation: rectal pressure should rise while the anal sphincter relaxes, and a sphincter that tightens instead marks the abnormal pattern.

  3. Resting pressure is recorded with the patient relaxed, before any maneuver.

  4. Sensation is tested by inflating a rectal balloon step by step, not by straining.

See the answer before picking
No. 5 of 18

A patient's lactulose breath test shows a methane level well above the normal cutoff with no significant hydrogen rise. Which symptom pattern does this finding MOST often accompany?

  1. Blood with urgency points to colitis or infection, which a breath test does not detect.

  2. Methane-producing archaea slow intestinal transit, so a high methane result (intestinal methanogen overgrowth) goes with constipation and bloating.

  3. Diarrhea is more typical of hydrogen-predominant overgrowth; reading methane the same way as hydrogen is the trap.

  4. Steatorrhea with weight loss suggests fat malabsorption from pancreatic or mucosal disease.

See the answer before picking
No. 6 of 18

A patient is scheduled for small-bowel video capsule endoscopy for suspected bleeding. Which preparation BEST improves the images?

  1. A purgative, often 2 L of PEG, clears residue and bubbles from the small bowel and improves what the capsule can see.

  2. Fiber leaves residue in the bowel that hides the mucosa from the camera.

  3. Clear liquids alone cleanse less well than a purgative, and three days of them add nothing.

  4. Barium coats the bowel and blocks the camera's view, so it is avoided before capsule studies.

See the answer before picking
No. 7 of 18

During the 7-day PPI washout before diagnostic pH monitoring, a patient asks what to take for heartburn. Which response by the nurse is BEST?

  1. H2 blockers also suppress acid and are stopped 2 to 3 days before testing, so they cannot run up to the study.

  2. Banning all relief is unnecessary and makes patients more likely to abandon the washout.

  3. Even an occasional PPI dose suppresses acid for days and spoils the off-therapy study.

  4. Antacids act briefly and are generally allowed during the washout until shortly before the study, so symptoms can be eased without masking reflux.

See the answer before picking
No. 8 of 18

A patient scheduled for solid-phase gastric emptying scintigraphy asks how long to plan for. Which response by the nurse is accurate?

  1. The 1-hour image is part of the series, but read alone it misses delayed emptying.

  2. Standardized solid-meal scintigraphy images the stomach at set points up to 4 hours, because shorter studies miss many cases of delayed emptying.

  3. Day-long imaging belongs to colonic transit studies, a different test.

  4. One early image cannot show the emptying curve; delay declares itself only at the later time points.

See the answer before picking
No. 9 of 18

During a percutaneous liver biopsy, how should the nurse position the patient for the needle pass?

  1. The needle goes in at the right midaxillary line, which this position blocks, and an arm at the side keeps the rib spaces narrow.

  2. Supine near the right edge of the bed with the right arm raised widens the intercostal spaces over the liver for the needle pass.

  3. Sitting forward is the thoracentesis position, a common mix-up between two bedside procedures.

  4. Prone positioning is used for kidney biopsy, not for the standard liver approach.

See the answer before picking
No. 10 of 18

Which pre-test instruction should the nurse give a patient scheduled for high-resolution esophageal manometry only?

  1. Prokinetics change esophageal contraction and LES pressure, so they are held before manometry as the lab's protocol directs.

  2. A fast of a few hours is enough; days of clear liquids are a colonoscopy-prep habit carried over to the wrong test.

  3. Oxybutynin is an anticholinergic that weakens esophageal contractions, so it is held as well rather than taken.

  4. The 7-day PPI stop belongs to off-therapy reflux monitoring; manometry alone does not require it.

See the answer before picking
No. 11 of 18

During 24-hour catheter-based pH-impedance monitoring, the patient calls to report the recorder cable came unplugged overnight while the nasal catheter is still in place. What should the nurse advise?

  1. The sensor sits a set distance above the LES; moving the catheter invalidates the data, so patients never reposition it.

  2. Pulling the catheter ends a study that can still produce a usable recording.

  3. With the catheter still in place, the patient plugs the recorder back in and writes down the time so the gap can be excluded from analysis.

  4. Usual meals are encouraged so typical reflux is captured; fasting would distort the result.

See the answer before picking
No. 12 of 18

After a percutaneous liver biopsy, the nurse positions the patient on the right side. What is the PRIMARY purpose?

  1. Bile leaking along the tract is a complication to prevent, not something positioning should encourage.

  2. Lying on the punctured side does not improve breathing; new dyspnea after a liver biopsy raises concern for pneumothorax or bleeding.

  3. Lying on the right side presses the liver against the ribs and compresses the capsular puncture, the main source of early bleeding.

  4. Aspiration is prevented by airway monitoring and recovery positioning, not specifically by lying on the right side.

See the answer before picking
No. 13 of 18

A patient taking metoclopramide has an early hydrogen rise on a lactulose breath test. What is the MOST likely cause of this result?

  1. Suppressed flora, as after antibiotics, blunts the rise and gives a false negative; metoclopramide has no antimicrobial effect.

  2. Inadequate fasting raises the baseline reading rather than producing an early rise after the substrate.

  3. A prokinetic hurries the sugar to colonic flora, so hydrogen rises early and mimics small-bowel overgrowth.

  4. Slow emptying would delay the peak, not bring it forward, and metoclopramide speeds emptying rather than slowing it.

See the answer before picking
No. 14 of 18

A wireless pH capsule is attached to the esophagus during EGD for 96-hour monitoring. Which safety instruction should the nurse include in the discharge teaching?

  1. The wireless capsule contains metal and a transmitter, and its labeling bars MRI within 30 days of placement, while it may still be attached or in the bowel.

  2. The capsule detaches on its own within days and passes in the stool; no removal visit is needed.

  3. Airport scanners are not a labeled hazard for the capsule.

  4. Usual meals are encouraged so the recording shows typical reflux.

See the answer before picking
No. 15 of 18

For catheter-based esophageal pH monitoring, where is the distal pH sensor positioned?

  1. At the border, swallowing and breathing can pull the sensor into the stomach, where gastric acid is misread as reflux.

  2. A gastric sensor measures stomach pH; reflux has to be recorded in the esophagus.

  3. By convention the distal sensor sits 5 cm above the manometrically located upper border of the LES, so it stays in the esophagus as the sphincter moves.

  4. This mixes up the upper and lower sphincters and puts the sensor high in the esophagus, where it misses most distal reflux.

See the answer before picking
No. 16 of 18

During the pre-procedure call for a percutaneous liver biopsy, which home medication must the nurse confirm was held as instructed by the provider?

  1. Lactulose has no effect on hemostasis, and stopping it can tip a patient with cirrhosis into hepatic encephalopathy.

  2. Thyroid replacement is taken as usual; it does not raise bleeding risk.

  3. The diuretic does not affect clotting and is usually continued; stopping it can let ascites build up.

  4. Percutaneous liver biopsy carries a high bleeding risk, so a DOAC is paused on a schedule the provider sets from the drug and kidney function, and the nurse confirms the last dose.

See the answer before picking
No. 17 of 18

During anorectal function testing, the patient cannot expel a 50-mL water-filled rectal balloon within 1 minute. What does this finding MOST LIKELY suggest?

  1. Incontinence shows up as low resting or squeeze pressures; a patient who cannot push the balloon out has the opposite problem.

  2. Hemorrhoids can bleed or prolapse, but they do not stop a small balloon from passing.

  3. Hypersensitivity means urgency at low balloon volumes during sensory testing, not an inability to evacuate.

  4. Failing to expel a 50-mL balloon within a minute points to an evacuation disorder in which the pelvic floor fails to relax, most often dyssynergic defecation.

See the answer before picking
No. 18 of 18

At 30 hours after ingestion, an abdominal X-ray shows the intact patency capsule in the colon. How does the nurse interpret this result?

  1. A patency capsule seen in the colon at the 30-hour check has cleared the small bowel intact, so the video capsule can go ahead.

  2. The capsule has already left the stomach and the small bowel; gastric emptying is not what this film assesses.

  3. A stricture would hold the dummy capsule in the small bowel, where it dissolves; reaching the colon rules that out.

  4. The dissolvable capsule is designed so that retention does not mean surgery, and here it was not retained at all.

See the answer before picking

–/18

Score for this set

Counted in this browser tab only: closing it clears the count, and no answer leaves your device.

Next topic: Sedation and patient monitoringAll CGRN topics on the blueprint

Subdomain 2B: tests the nurse performs

  • Procedures and equipment: diagnostic and therapeutic procedures outside the scope, with their catheters, recorders, balloons, capsules and needles.
  • Environment of care: the time-out and spills, as in the procedure room.
  • Pharmacology: what the patient needs to learn about holding or taking drugs, sedation where used, reversal agents, procedure and resuscitation drugs, and biologics.
  • Risks and specimens: possible complications and their care; collecting, labeling, storing and sending fluid and tissue.
  • Wellness: anatomy and physiology behind each test and the patient's wider needs around it.

Reflux testing: catheter, wireless capsule and impedance

Ambulatory reflux monitoring comes in two forms. A transnasal catheter records for about 24 hours; with impedance sensors added, it detects weakly acidic and nonacid reflux as well as acid, and it can be done on or off acid suppression. A wireless pH capsule, often called by the brand name Bravo, is attached to the esophageal wall during EGD and records for 48 to 96 hours, so the patient can eat and work more normally.

The Lyon Consensus 2.0 (2024) sets the rule of thumb for which test to order. When GERD has not been proven, testing is done off PPIs, and prolonged wireless monitoring is preferred. When GERD is already proven by endoscopy or earlier testing and symptoms continue, impedance-pH testing is done on therapy. The consensus also defines the acid exposure thresholds that count as conclusive.

For the patient, the diary matters as much as the device: meals, lying down and each symptom are logged with the time, because the analysis links symptoms to reflux events. GERD teaching after the result is on GI disorders and care plans.

Manometry of the esophagus and the anorectum

High-resolution esophageal manometry maps pressure along the whole esophagus during a series of water swallows, read against the Chicago Classification of esophageal motility disorders, version 4.0 (2021), which added upright as well as supine swallows. The patient must be awake to swallow on command, so the test is done without sedation after a topical anesthetic in the nose.

Anorectal manometry measures resting and squeeze pressures, rectal sensation and the push maneuver, and the London Classification of anorectal function (2020), from the International Anorectal Physiology Working Group, reads it together with a balloon expulsion test. Both tests can make patients anxious and embarrassed: privacy, a clear explanation and a chaperone where your policy calls for one are part of the nursing role the blueprint names.

Breath tests and gastric emptying

Hydrogen and methane breath tests measure gases made when bacteria ferment a sugar. Glucose or lactulose is used for small intestinal bacterial overgrowth; lactose or fructose for malabsorption. Under the North American consensus on breath testing (2017), patients avoid antibiotics for 4 weeks before, eat a low-fermentation diet the day before, fast for 8 to 12 hours and do not smoke on the day. Methane is reported on its own line, separate from hydrogen.

Gastric emptying scintigraphy follows a standardized low-fat egg-white meal with a radiotracer and serial images, as set out in the consensus on standardized gastric emptying scintigraphy (2008). Drugs that speed or slow the stomach (prokinetics, opioids, anticholinergics, GLP-1 receptor agonists) are reviewed with the ordering provider beforehand, and blood glucose is checked in patients with diabetes, because hyperglycemia slows emptying.

Paracentesis and percutaneous liver biopsy

Paracentesis drains ascitic fluid for diagnosis or relief. Before the procedure: consent, baseline vital signs and weight, an empty bladder, and the site chosen under ultrasound. Afterward: vital signs, the puncture site and leakage, and the volume removed. For large-volume paracentesis of more than 5 liters, the AASLD practice guidance on ascites (2021) recommends albumin, 6 to 8 g for each liter removed, to protect against circulatory dysfunction.

Liver biopsy is percutaneous or transjugular; the transjugular route is used when clotting is poor or ascites is massive. Recent platelets and coagulation tests are on the chart beforehand, and the patient is watched closely in the first hours afterward, when most bleeding shows up, per the AASLD position paper on liver biopsy (2009). Right shoulder pain can be referred from the diaphragm, but pain that grows, falling blood pressure or a rising pulse mean bleeding until proven otherwise. The liver diseases behind both procedures are on liver, pancreas and biliary disease.

Reflux, motility and liver test errors

Easy to confuse in 2B

  • Testing on PPIs to make the diagnosis. Off-PPI testing proves GERD; on-PPI impedance testing judges ongoing symptoms in GERD already proven.
  • Assuming pH alone sees all reflux. A pH sensor misses weakly acidic and nonacid events; impedance detects them.
  • Sedating for esophageal manometry. The test needs the patient awake to swallow on command.
  • Calling a paracentesis a thoracentesis. Paracentesis drains the peritoneal cavity; thoracentesis drains the pleural space.
  • Expecting late bleeding after liver biopsy. Most bleeding appears in the first hours, which is why the early checks are frequent.

CGRN review for the motility lab

Pick your phone’s store:

App StoreGoogle Play

Common questions about 2B tests

How does a Bravo test differ from impedance-pH monitoring?

A Bravo-type wireless capsule measures acid only, for 48 to 96 hours, without a tube. A catheter with impedance sensors records for about 24 hours and also detects reflux that is not acidic.

Why are PPIs stopped before some pH studies?

Off-PPI testing is how GERD is proven when the diagnosis is still open, so acid suppression is held for the period the ordering provider sets.

Are biologic infusions part of non-endoscopic procedures on the CGRN?

Yes, in part: the 2B pharmacology line names biologics, and the pharmacology lines of 3B and 3C name them again.

Next topic

Sedation and patient monitoring

Part of Domain 3 · Patient Care Interventions (25%) · also 2A

Open the next topic

Every CGRN topic page, by blueprint domain

Domain 4 · 19%

Environmental Safety, Infection Prevention and Control

Documents behind the numbers

  1. ABCGN: CGRN Exam Test Blueprint, effective May 1, 2023 (PDF), pp. 1–3abcgn.org; we opened it Nov 17, 2026
  2. ABCGN: Certification Handbook, May 2025 edition (PDF), pp. 3–12 and Appendix A–Babcgn.org; we opened it Nov 17, 2026
  3. Lyon Consensus 2.0 (2024)doi.org; we opened it Nov 17, 2026
  4. Chicago Classification of esophageal motility disorders, version 4.0 (2021)doi.org; we opened it Nov 17, 2026
  5. London Classification of anorectal function (2020)doi.org; we opened it Nov 17, 2026
  6. North American consensus on breath testing (2017)doi.org; we opened it Nov 17, 2026
  7. consensus on standardized gastric emptying scintigraphy (2008)doi.org; we opened it Nov 17, 2026
  8. AASLD practice guidance on ascites (2021)doi.org; we opened it Nov 17, 2026
  9. AASLD position paper on liver biopsy (2009)doi.org; we opened it Nov 17, 2026